IEC60061 Go and Not Go Gauges for Lampholder and Caps

Issuing time:2016-06-03 18:49

The lamp cap and lampholder gauges are designed according to IEC60061-3:2004,the structure and waveform are calculated by PC to reach high precision, and the appearance looks nice. The material is applied alloy steel. All the products equip with third-lab certificate authorized by CNAS.  The gauges list as below:

ItemFigure No.Description
E27
17006-27B-1
“Go” gauge for E27 caps on finished lamps
27006-27C-1
“Go” gauge for dimension “S1” of E27 caps on finished lamps
37006-28A-1
“Not Go” gauge for E27 caps on finished lamps
47006-50-1
Gauge for finished lamps fitted with E27 caps for testing contact making
57006-51-2
Gauge for caps on finished lamps for testing protection against accidental contact
67006-51A-2
Gauge for caps on finished lamps for testing protection against accidental contact during insertion
E14
17006-27F-1
“Go” gauge for E14 caps  on finished lamps
27006-27G-1
“Go” gauge for dimension “S1” of E14 caps on finished lamps
37006-28B-1
“Not Go” gauge for E14 caps on finished lamps
47006-54-2
Gauge for finished lamps fitted with E14 caps for testing contact making
57006-55-2
Gauge for finished lamps fitted with E14 caps for testing protection against accidental contact
E12
17006-27H-1
“Go” gauge for caps on finished lamps
27006-27J-1
Additional “Go” gauge for caps on finished lamps
37006-28C-1
“Not Go” gauge for caps on finished lamps
47006-32-1
gauge for finished lamps fitted with E12 caps for testing contact-making
E26
17006-27D-3
“Go” gauge for caps
27006-29L-4
“Not Go” gauge for caps
37006-29-3
Gauge for testing contact-making of lamps fitted with caps
E17
17006-27K-1
“Go” gauge for caps on finished lamps E17
27006-28F-1
“Not Go" gauge for caps on finished lamps E17
37006-26D-1
Gauge for testing contact-making of lamps fitted with caps E17
E39
17006-24A-1
Gauge for finished lamps fitted with E39 caps for testing contact-making
27006-24B-1
“Go” gauge for caps on finished lamps E39
37006-24C-1
Gauge for testing contact-making of lamps fitted with caps E39
E40
17006-27-7
“Go” gauge for caps on finished lamps
27006-28D-1
“Not Go” Gauge for caps on finished lamps
37006-52-1
Gauge for finished lamps fitted with E40 caps for testing contact making
47006-53-1Gauge for finished lamps fitted with E40 caps for testing protection against accidental contact
G13
17006-44-4
“Go” and “Not Go” gauge for unmounted Bi-Pin cap
27006-45-4“Go” gauge for BI-Pin cap on finished lamps
GU10
17006-121-1
Go and Not Go Gauge for Bases
B22 & B22D
17006-10-8
Not Go Gauge for Caps on Finished Lamps
27006-11-8
Go gauge for Caps on Finished lamps BA9, B15, BA15 & B22
37006-4A-2
Gauges for Testing the Insertion of Caps in lampholders B15d, B22d & BY22d
47006-4B-1
Gauges for Testing the Retention of B15d and B22d Caps in the Holder
57006-3-1
Acceptance Gauge for B22d Caps Intended for Automatic Wire Threading
67006-17A-1
Go Gauge for Cap on Finished Lamps BY22d
G5
17006-46-3
Go and Not Go gauge for Unmounted BI-PIN Cap
27006-46A-3
“Go” Gauge for BI-PIN Cap on Finished Lamps
Article classification: Industry Trends
Share to:
Contact us

PEGO GROUP (HK) COMPANY LIMITED

Address:   Flat/RM803, Chevalier House,45-51 Chatham Road South, Tisim Sha Tsui,Kowloon, Hong Kong

E-MAIL: salesHK@pegotester.com

WEB: http://www.pegotester.com/   

          http://www.electricalsafety-testequipment.com/


PEGO ELECTRONICS (YI CHUN) CO., LTD.

ADDRESS: No. 429, Yichun South Road ( Happiness Park),   Yuanzhou District, Yichun, Jiangxi, 336000, China

E-MAIL: sales@pegotester.com, service@pegotester.com

TEL: 86-(0)795-3560528   FAX: 4008266163 ext. 29929

CS
 
 
website qrcode

Mobile Website