No.
| Gauge description
| Figure number
| Model
|
1 | Maximum retaining force gauge (15A125V two-pole) | JIS C8303 Figure A.1 JIS C8282-1: 2010 CL22.1
| J3-DA1
|
2 | Minimum retaining force gauge (15A125V two-pole)
| JIS C8303 Figure A.1 JIS C8282-1: 2010 CL22.2
| J3-XA1
|
3 | Test plug for temperature rise test (15A125V two-pole)
| JIS C8303 Figure A.1 JIS C8282-1: 2010 CL19
| J3-WA1
|
4 | Breaking capacity, normal operation gauge
| JIS C8303 Figure A.1 JIS C8282-1: 2010 CL20/21
| J3-FA1
|
5 | Maximum retaining force gauge (15A125V two-pole)
| JIS C8303 Figure A.2 JIS C8282-1: 2010 CL22.1
| J3-DA2
|
6 | Minimum retaining force gauge (15A125V two-pole)
| JIS C8303 Figure A.2 JIS C8282-1: 2010 CL22.2
| J3-XA2
|
7 | Test plug for temperature rise test (15A125V two-pole)
| JIS C8303 Figure A.2 JIS C8282-1: 2010 CL19
| J3-WA2
|
8 | Breaking capacity, normal operation gauge
| JIS C8303 Figure A.2 JIS C8282-1: 2010 CL20/21
| J3-FA2
|
9 | Maximum retaining force gauge (20A 125V two-pole)
| JIS C8303 Figure A.3 JIS C8282-1: 2010 CL22.1
| J3-DA3
|
10 | Minimum retaining force gauge (20A 125V two-pole)
| JIS C8303Figure A.3 JIS C8282-1: 2010 CL22.2
| J3-XA3
|
11 | Test plug for temperature rise test (20A 125V two-pole)
| JIS C8303 Figure A.3 JIS C8282-1: 2010 CL19
| J3-WA3
|
12 | Breaking capacity, normal operation gauge
| JIS C8303 Figure A.3 JIS C8282-1: 2010 CL20/21
| J3-FA3
|
13 | Maximum retaining force gauge (20A 250V two-pole)
| JIS C8303 Figure A.4 JIS C8282-1: 2010 CL22.1
| J3-DA4
|
14 | Minimum retaining force gauge (20A 250V two-pole)
| JIS C8303 Figure A.4 JIS C8282-1: 2010 CL22.2
| J3-XA4
|
15 | Test plug for temperature rise test (20A 250V two-pole) | JIS C8303 Figure A.4 JIS C8282-1: 2010 CL19
| J3-WA4
|
16 | Breaking capacity, normal operation gauge
| JIS C8303 Figure A.4 JIS C8282-1: 2010 CL20/21
| J3-FA4
|
17 | Maximum retaining force gauge (30A 250V two-pole)
| JIS C8303 Figure A.5 JIS C8282-1: 2010 CL22.1
| J3-DA5
|
18 | Minimum retaining force gauge (30A 250V two-pole)
| JIS C8303 Figure A.5 JIS C8282-1: 2010 CL22.2
| J3-XA5
|
19 | Test plug for temperature rise test (30A 250V two-pole)
| JIS C8303 Figure A.5 JIS C8282-1: 2010 CL19
| J3-WA5
|
20 | Breaking capacity, normal operation gauge
| JIS C8303 Figure A.5 JIS C8282-1:2010 CL20/21
| J3-FA5
|
21 | Maximum retaining force gauge (15A 125V two-pole+ earthing-pin)
| JIS C8303 Figure A.9 JIS C8282-1:2010 CL22.1
| J3-DA9
|
22 | Minimum retaining force gauge (15A 125V two-pole+ earthing-pin)
| JIS C8303 Figure A.9 JIS C8282-1:2010 CL22.2
| J3-XA9
|
23 | Test plug for temperature rise test (15A 125V two-pole+ earthing-pin)
| JIS C8303 Figure A.9 JIS C8282-1:2010 CL19
| J3-WA9
|
24 | Breaking capacity, normal operation gauge
| JIS C8303 Figure A.9 JIS C8282-1:2010 CL20/21
| J3-FA9
|
25 | Maximum retaining force gauge (15A 250V two-pole+ earthing-pin)
| JIS C8303 Figure A.10 JIS C8282-1: 2010 CL22.1
| J3-DA10
|
26 | Minimum retaining force gauge (15A 250V two-pole +earthing-pin)
| JIS C8303 Figure A.10 JIS C8282-1: 2010 CL22.2
| J3-XA10
|
27 | Test plug for temperature rise test (15A 250V two-pole + earthing-pin)
| JIS C8303 Figure A.10 JIS C8282-1: 2010 CL19
| J3-WA10
|
28 | Breaking capacity, normal operation gauge
| JIS C8303 Figure A.10 JIS C8282-1: 2010 CL20/21
| J3-FA10
|
29 | Maximum retaining force gauge (15A 125V two-pole+ earthing-pin)
| JIS C8303 Figure A.11 JIS C8282-1: 2010 CL22.1
| J3-DA11
|
30 | Minimum retaining force gauge (15A 125V two-pole+ earthing-pin)
| JIS C8303 Figure A.11 JIS C8282-1: 2010 CL22.2
| J3-XA11
|
31 | Test plug for temperature rise test (15A 125V two-pole+ earthing-pin)
| JIS C8303 Figure A.11 JIS C8282-1: 2010 CL19
| J3-WA11
|
32 | Breaking capacity, normal operation gauge
| JIS C8303 Figure A.11 JIS C8282-1: 2010 CL20/21
| J3-FA11 |