EFT and Surge Generator
1. Introduction
EFT and Surge Generator is applied to check the performance of the power cable and inner electrical circuit of equipment (home appliances, communication electronics, electrical components, auto control system and etc.) against the high energy transient interference caused by switching and lightning transients. The equipment meet the requirements of IEC61000-4-5 and IEC61000-4-4.
Burst and surge generator is a 2 in 1 equipment, it can do both the fast transient immunity test and surge immunity test in an economic way.
2. Features
1) 7 inches LCD touch screen, with plenty of functions, easy to operation
2) 1000 groups memories
3) Surge voltage and current waveforms can be monitoring at real time by connect with an oscilloscope.
4) Built-in single phase 10A (16A) network, 2 in 1 design.
5) Equip with industrial standard socket-outlet for EUT.
6) Buit-in working voltage and current monitoring.
7) Over-voltage, over-current and short-circuit protection
8) Alarm at voltage error and no output
9) It has self-diagnosis function, can judget obnormal high voltage and surge output.
3. Parameters of lighting surge generator
Output voltage (open) | 6kV (Max) ±5% |
Frontier time | 1.2μs ±30% |
Time to half-value | 50μs ±20% |
Output current (short) | 3kA ±5% (max) |
Frontier time | 8μs ±20% |
Time to half-value | 20μs ±20% |
Output polarity | Positive, negative, positive/negative automatically |
Output impedance | 2Ω±10% |
Surge trigger mode | Synchronization,asynchronization |
Inject phase | Freely set at 0-360°,resolution:1° |
Trigger mode | Auto or manual, single |
Surge times | 1-9999 times |
Memories | Buit-in IEC standard or customized, 1000 groups |
Surge interval | 20-9999s |
Surge voltage monitoring attenuation ratio | 1000:1 |
Surge current monitoring attenuation ratio | 1000:1 |
Accuracy | Superior 5% |
Peak surge voltage and current display | LCD synchronous display |
Surge voltage and current monitoring output | BNC Coaxial terminal,≥1MΩ |
Voltage and current of EUT monitoring | LCD real time display: AC voltage and current |
CDN
| AC: single phase 300V,10A(16AMax), 50/60Hz |
DC: 300V, 10A (16AMax) |
Coupling mode | L-N |
L-PE, N-PE, L+N-PE |
Coupled device | L-N | 18μF capacitance |
L-PE, N-PE, L+N-PE | 10Ω resistor +9μF capacitance |
Working environment | Tempereature: 15°C-35°C, R.H.: 10%-75% |
Power supply | AC220±10%, 50/60Hz |
Dimension | 470mm* 260mm* 500mm (W*H*D) |
Parameters of EFT Generator
open circuit output voltage | 0.25-5kV ±5% |
50Ω load output voltage | 0.125-2.5kV ±5% |
Wave sharp of the pulse | 5/50ns, 50Ω/1000Ωload |
Rise time | 5ns ±30%, 50Ω load |
5ns ±30%, 1000Ω load |
duration | 50ns ±30%, 50Ω load |
50ns -15/+100ns, 000Ω load |
Impedance | 50Ω ±20% |
Output polarity | Negative/positive |
Repetition frequency | 0.1-1200.0kHz ±10% |
burst duration | Standard | 15ms@2.5kHz/5kHz,750μs@100kHz,250μs@300kHz |
Adjustable | Nos of pulse can adjust at 1-255 Burst duration=(pulse number-1)/repetition frequency |
Burst period | 100-999ms |
Burst mode | Synchronous or asynchronous |
Synchronous phase | Free set at 0-3600 , resolution: 10 |
Test function: |
IEC standard or set test mode freely (1000 groups) |
Built-in coupling and decoupling network (3-phrase and 5 wires) | AC | 3-phrase 380V,16A, 50/60Hz |
DC | 380V,16A (Max) |
Coupling mode | L1,L2, L3, N,PE,freely setup |
Coupling capacitors: | 33nF ±10% |
Environment requirements | Temperature:15°C-35°C; Humidity: 10%-75% |
Power requirements | AC220±10%,50/60Hz, 300W |