EMI Conducted Interference Test System
1. Configuration
Name | Model | Description |
EMI Conducted Interference Test System (Includes Artificial mains network (LISN), receiver, software) | EMC500 | Test range: 9K~300MHz. Among them, 30M~300MHz is radiation disturbance test for luminaire and household appliance. |
Isolation Transformer | DAG | 500W-2 pieces, 1000W-1 pieces |
Attenuator | CY371-2-4-20 | 20dB |
CDN | CDN-M2 | Equip with EMC500 to test radiation disturbance |
Attenuator | CY371-2-4-20 | 6dB |
2. Specification
Frequency sweep range | 9KHz~300MHz |
Peak value, quasi-peak value, average value level range | 20dBμV~120dBμV |
Scanning bandwidth | 9kHz~150kHz: 200Hz 150kHz~30MHz: 9kHz 30MHz~300MHz: 120kHz |
Scanning steps | 9kHz~150kHz:100Hz, 200Hz, 400Hz (optional) 150kHz~30MHz: 5kHz, 10kHz, 20kHz (optional) 30MHz~300MHz: 50kHz, 100kHz, 200kHz (optional) |
Test time | 9kHz~150kHz | 50~500ms (peak, settable) 4000~15000ms (quasi-peak, settable) |
150kHz~30MHz | 5~500ms (average/peak, settable) 2000~15000ms (quasi-peak, settable) |
30MHz~300MHz | 2~500ms (average/peak, settable) 1000~8000ms (quasi-peak, settable) |
Total uncertainty | ±3dB |
Input impedance | 50Ω |
Input signal (max) | 2V, protect at 5V |
Software | Built-in GB17743, FCC, EN55015, GB4343 standards, and support user-defined. |
Working power | 220V/50Hz±10% |