Standard/figure number | Gauge name | Qty | Test Purpose |
GB/T 1002-2021, Figure 8 | Single Phase Two-Pole Plug Gauge (≤10A) | 1 | The pins of the plug shall be able to pass the gauges shown in Figures 8 and 9. If the plug pin is provided with an insulating sheath, the insulating sheath part does not need to pass the gauge in Figure 8 and Figure 9.
The plugs can smoothly plug-in and pull out in vertical and horizontal directions with a small force shows qualified, Otherwise, the distance between the pins or the inclination and position of the pins do not match.
Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1. |
GB/T 1002-2021, Figure 9 | Single Phase Two-Pole with Earth Plug Gauge (10A, 16A) | 2 |
GB/T 1002-2021, Figure 10 | Go Gauge for Single Phase Two-Pole socket-Outlet (10A) | 1 | The Go Gauges shall be able to insert into the jacks of the socket-outlet.
The Go Gauges can smoothly insert into the jacks of the socket-outlet in verticall directions with a small force shows qualitified. Otherwise, the spacing, inclination, position, jacks of the socket-outlet do not match.
Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1. |
GB/T 1002-2021, Figure 11 | Go Gauge for single Phase Two-Pole Socket-Outlet with Earthing (10A, 16A) | 2 |
GB/T 1002-2021, Figure 12 | Not Go Gauge for Single Pin of Single Phase Socket-Outlet (10A, 16A) | 2 | The Not Go Gauge shall be not able to insert into the jacks of the socket-outlet.
The Not Go Gauge can not smoothly insert into the jacks of the socket-outlet in vertical direction with a small force shows qualitified. Otherwise, the size of jacks of the socket-outlet do not match.
Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1. |
GB/T 1002-2021, Figure 13 | Non-Contact Gauge for Single Phase Two-Pole Socket-Outlet (10A) | 1 | Th Non-Contact Gauges shall not be able to contact the live kits of socket-outlet.
The non-contact gauges can smoothly insert into the jacks of the socket-outlet in vertical and horizontal directions with a small force, but cannot contact the copper sets (female terminal) shows qualified, Otherwise, the sizes of the socket-outlet does not match.
Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1. |
GB/T 1002-2021, Figure 14 | Non-Contact Gauge for Single Phase Two-Pole Socket-Outlet with Earthing (10A, 16A) | 2 |
GB/T 1002-2021, Figure 15 | Contact Gauge for Single Phase Two-Poles Socket-Outlet (10A) | 1 | The contact gauge shall be able to contact the live kits of socket-outlet.
The contact gauges can smoothly insert into the jacks of the socket-outlet in vertical and horizontal directions with a small force and contact the copper sets (female terminal) shows qualified, Otherwise, the sizes of the socket-outlet does not match.
Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1. |
GB/T 1002-2021, Figure 16 | Contact Gauge for Single Phase Two-Poles Socket-Outlet with Earthing (10A,16A) | 2 |