The IK mechanical impact test apparatus can meet the test requirements of IEC60068-2-75 Test Eha and Test Ehc, IEC62262, IEC60598, EN50102, GB2423.55-2006, GB20138-2006 and etc.. It is apply to sheet metal, household appliance, luminaire, EVCS and etc. for mechanical impact testing.
This equipment is consisted by striking elements ( (≤1J/0.25kg *1, 2J/0.5kg*2, 5J/1.7kg*2, 10J/5kg*2, 20J/5kg*2), swing pipes, guideways and test rig, striking elements work with swing pipes to perform IK01 to IK10 pendulum hammer impact tests, striking elements work with guideways to perform IK07 to IK10 impact hammer impact tests. The test rig is made of aluminum alloy, with four wheels at the bottom, and the whole device can move freely.
2. Parameter
Swing Pipe | Steel pipe (Length: 1000mm, outer diameter: 15.9mm, thickness: 1.5mm), equip with hammers to equivalent mass |
Lifting stroke | 200-1500mm (for pendulum and vertical impacts test) 200-2300mm (for ball impact test) |
Drop mode | Button control and electromagnet instantaneous release (for vertical impact and ball impact tests) Manual control (for pendulum impact test) |
Impact hammers | 0.25kg nylon hammer for IK01 to IK06 Pendulum Impact Test 0.5kg, 1.7kg, 5kg, 5kg steel hammers for IK07 to IK10 Pendulum impact and vertical impact tests |
Guideway | 200mm, 300mm, 400mm |
Impact balls | Φ50mm and Φ100mm |
Working power | 220V/50Hz |
Characteristics of Striking Elements |
Energy/J | ≤1 ±10% | 2 ±5% | 5 ±5% | 10 ±5% | 20 ±5% | 50 ±5% |
Equivalent mass±2%kg | 0.25(0.2) | 0.5 | 1.7 | 5 | 5 | 10 |
Material | Nylon | steel |
R/mm | 10 | 25 | 25 | 50 | 50 | 50 |
D/mm | 18.5(20) | 35 | 60 | 80 | 100 | 125 |
f/mm | 6.2(10) | 7 | 10 | 20 | 20 | 25 |
r/mm | - | - | 6 | - | 10 | 17 |
l/mm | Depends |
Fall Height |
Energy/J | 0.14 | 0.2 | (0.3) | 0.35 | (0.4) | 0.5 | 0.7 | 1 | 2 | 5 | 10 | 20 | 50 |
Equivalent mass/kg | 0.25 | (0.2) | 0.25 | (0.2) | 0.25 | (0.2) | (0.2) | 0.25 | 0.25 | 0 .25 | 0.5 | 1.7 | 5 | 5 | 10 |
Fall height±1%mm | 56 | (100) | 80 | (150) | 140 | (200) | (250) | 200 | 280 | 400 | 400 | 300 | 200 | 400 | 500 |
Degrees of protection against external mechanical impacts
IK01 | IK02 | IK03 | IK04 | IK05 | IK06 | IK07 | IK08 | IK09 | IK10 |
0.14J | 0.2J | 0.35J | 0.5J | 0.7J | 1J | 2J | 5J | 10J | 20J |