Description | This equipment is designed according to JISD0203 R1/R2/S1/S2, IEC60529, ISO20653 for automobile parts testing. | Model | PG-JISD34 |
JIS D0203 IP Waterproof Test Machine 1. Introduction
The waterproof test chamber is designed to meet the test requirements of JIS D0203 for R1/R2/S1/S2 tests and IEC60529 for IPX3/IPX4/4K tests. The rotating tube with 2 rain nozzles for R1/ R2 rain tests, the rotating tube with 40 spray nozzles for S1/S2 spray tests, both are strictly designed according to JISD0203. The oscillating tube for IPX3/4 testing is strictly designed according to IEC60529, the tube radius is R400 which has 25 nozzles and 0.4 diameter. This equipment puts the coil and the oscillating tube in a test chamber, R1, R2, S1, S2 tests can be carried out separately or simultaneously, and IPX3, IPX4, IPX4K tests can be carried out separately. A waterproof socket-outlet for specimen is attached on the wall of the test chamber to support live test, the front panel is transparent for easy observation of the experimental process.
Type | Symbol | Test Purpose | Test Method | Rain Test | R1 | Auto parts against water direct contact | water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min | R2 | Auto parts against rain or spray water indirect contact | water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min | Spray Test | S1 | Auto parts against rain or jet water direct contact | water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min | S2 | Auto parts against riptide | water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h | Spray Test | IPX3 | Enclosure against spraying water | spray±60 degrees from vertical, water flow: 0.07L/min±5% per hole, test time: 10min | IPX4 | Enclosure against splashing water | spray±180 degrees from vertical, water flow: 0.07L/min±5% per hole, test time: 10min |
2. Parameters
Working Chamber Size | 1000*1000*1000mm (L*D*H) | Dimension | 1500*1380*2000mm (L*D*H) | Turntable Diameter | ¢400mm | Turntable Load Weight | 50KG | Lifting height | 450-750 mm | Turntable Speed | 1 -20r/min | Turntable Angle | 0° or 15° (Horizontal) | Test Time | 0-999 min | Weight | About 250kg | Parameters of IPX3/4 | Rube Radius | 400mm | Tube Flow | IPX3=1.1L/min; IPX4=1.8L/min IPX4K=15L/min(0-18L/min adjustable) | Pressure | IPX3=80Kpa, IPX4=80Kpa; IPX4K=400Kpa (0-500Kpa adjustable) | Aperture of drop (mm) | IPX3-4=0.4mm, IPX4K=0.8mm | Aperture interval | 50mm | Tube inner diameter | 15mm | Tube angle | 120º (IPX3), 350º (IPX4) or custom setting | Tube speed | Back and forth at 1200: 4s; back and forth at 3600:12s | Parameter of JIS D0203 R1/R2 | Rain nozzle | Strictly designed according to the figure of JIS D0203 standard | Pressure | R1=0.01MPa, R2=0.03MPa | Nozzle number | 2pcs | Spray water time range | 0~99h59m, settable | Tube rotates around the shaft | 1~23r/min, adjustable | Parameter of JIS D0203 S1/S2 | Spray Nozzle | Strictly designed according to the figure of JIS D0203 standard | Pressure | S1=0.1MPa, S2=0.3MPa | Nozzle diameter | Φ1.2mm | Nozzle number | 40pcs | Spray water time range | 0~99h59m, settable | Tube rotates around the shaft | 1~23r/min, adjustable | Electric Parameter | Power supply | 220V | Power supply of specimen | 220V | Power | 1.0KW | Safety protection function | Leakage protection, water shortage protection, short circuit protection |
|