Category
Product Detail
Share to:

Apparatus for Checking Damage to Conductors

 
Detail
Description The apparatus for checking damage to conductors is designed to meet the test requirements of IEC60884-1:2022 clause 12.2.5 and figure 13 and IEC60669-1 Model PG-ADG

Apparatus for Checking Damage to Conductors

1. Introduction

The apparatus for checking damage to conductors is designed to meet the test requirements of IEC60884-1:2022 clause 12.2.5 and figure 13 and IEC60669-1. It is applied to checking if the terminal with screw clamping or screwless clamping can withstand the mechanical stress in normal use, and judging whether the design and structure of the screw clamping terminal meet the requirements of not excessively damaging the conductor when it clamps the conductor.


2. Specification

Control mode

Electric control

Working station

1

Working speed

10±2r/min

Bushing rotation diameter

75mm

Test time

0-99min59s (test time can be preset, and stop automatically when time up)

Configured mass

0.3KG,0.4KG, 0.7KG, 0.9KG, 1.4KG, 2.0KG

Test height

260mm, 280mm, 300mm, 320mm

Diameter of f bushing hole

6.5mm, 9.5mm, 13mm, 14.5mm

Height adjusting mode

Manual adjustable

Dimension and weight

L530mm*D500mm*H800mm/80kg

Working power

AC220±10%, 50/60Hz

Working condition

5-35℃ (temp.), 30%-90%R.H.