Maximum and minimum withdrawal force Test Apparatus
1. Introduction
Socket and plug withdrawal force test er is designed to meet the exacting requirements of major international standards such as IEC 60884-1 Fig 18 and Fig 19. The clamping system is easy to operate. The top plate swivels up from a horizontal position to a vertical orientation and the clamping device can be rotated in the top plate. These features allow the device to be set up in many different configurations to meet different standard requirements. Standard plugs and weights are supplied to perform testing on sockets rated up to 16A. Test plugs made from hardened steel with roughness not exceeding 0.8mm.Top plate pivots from horizontal to vertical.
2. Specification
● Standard configuration: 2-pin 10A plug, 3-pin 10A plug, 3-pin 16A plug, 10A and 16A pin gauges
● Includes weights and clamp for each one set.
Rated value | Polarity | withdrawal force |
Max for multiplex pin gauge | Min for single pin gauge | Max for single pin gauge |
≤10A | 2 | 40 | 1.5 | 17 |
3 | 50 |
>10A~16A | 2 | 50 | 2 | 18 |
3 | 54 |
>3 | 70 |
>16A~32A | 2 | 80 | 3 | 27 |
3 | 80 |
>3 | 100 |